POWER R-Line 4B and 4F-ELCT/GNRL/021

Material Supply SKU #: Z-POWER-R-LINE-4B-AND-4F-ELCT-GN-3608

SAR 0.00
/ Each
In Stock — Ships Today
Delivery by tomorrow when ordered by 4PM
Free Shipping over SAR 200
365-Day Returns
Secure Checkout
    n
  • Pow-R-Line 4B panel board utilizes circuit breakers. Pow-R-Line 4F Panelboards utilizes types FDPW fusible switches.
  • n
  • A single chassis accommodates both circuit breakers and fusible switches.
  • n
  • Main and neutral are located at the same ends to provide additional space for branch devices.
  • n
  • Three-piece trim facilities installations.
  • n
  • Will accommodate Series C Circuit Breakers to provide higher ratings in a standard chassis and increased series ratings.
  • n
  • UL tested and listed. Meets NEC and NEMA tandards.
  • n
    n
  • Pow-R-Line 4B panel board utilizes circuit breakers. Pow-R-Line 4F Panelboards utilizes types FDPW fusible switches.
  • n
  • A single chassis accommodates both circuit breakers and fusible switches.
  • n
  • Main and neutral are located at the same ends to provide additional space for branch devices.
  • n
  • Three-piece trim facilities installations.
  • n
  • Will accommodate Series C Circuit Breakers to provide higher ratings in a standard chassis and increased series ratings.
  • n
  • UL tested and listed. Meets NEC and NEMA tandards.
  • n
n

General Construction Features

n WESCOSA assembled Panelboards as per Cutler-Hammer technologies are designed for sequence phase connection of branch circuit devices. This allows complete flexibility of circuit arrangement (1-, 2- or 3-poles) to allow balance of the electrical load on each phase.Sturdy rigid chassis assembly assures accurate alignment of interior with panel front; prevents flexing and minimizes possibility of loosening or damage to current carrying parts during and after installation.Four-point in-and-out adjustment of panel interior is provided to meet critical depth dimension on flush installations. This compensates for possible alignment of box at installation. Main lungs are mechanical  solder less type and approved for copper of aluminum conductors. n

TECHNICAL DATA

n Table 1: Panelboards Selection Guide n n  n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n
  n n  n n  n n  n nPanelboard Type  n n  n n  n n  n n  n nDevice Type  n nMaximum Voltage Rating  n nMaximum Main Rating, Amperes  n n  n nBranch Circuit n nAmpere RangeShort Circuit Current n nRatings rms Symmetrical Amperes, AC
  n n  n nAC  n n  n nDC  n nMain Lugs Only  n nMain Device  n nFully Rated (kA)  n nSeries Rated (kA)
Pow-R-Line 1aBreaker240-60060015 – 10010 – 2222 – 200
Pow-R-Line 2aBreaker240 n n480Y/227250600 n n600600 n n60015 – 100 n n15 – 10065 n n1465 – 200 n n22 – 150
Pow-R-Line 3aBreaker240 n n480 n n600250800 n n800 n n800600 n n600 n n60015 – 225 n n15 – 225 n n15 – 22510 – 200 n n14 – 100 n n14 – 3522 – 200 n n22 – 150 n n-
Pow-R-Line 4bBreaker240 n n480 n n6002501200 n n1200 n n12001200 n n1200 n n120015 – 1200 n n15 – 1200 n n15 – 120010 – 200 n n14 – 200 n n14 – 20022 – 200 n n22 – 150 n n-
Pow-R-Line 4fFusible Switch240 n n6002501200 n n12001200 n n120030 – 1200 n n30 – 1200100 – 200 n n100 – 200- n n-
n

Table 2: Standard Main Lug Terminals

n  n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n
  n nPanel TypeWire Size Ranges for Ampere Capacity
100 n nAmps  n n225 Amps  n n250 Amps  n n400 Amps  n n600 Amps  n n800 Amps  n n1200 Amps
Pow-R-Line 1a#12–1/0#6–300 kcmil-(2) #2–500 kcmil---
Pow-R-Line 2a#12–1/0#6–300 kcmil-(2) #2–500 kcmil---
Pow-R-Line 3a#12–1/0-#6 – 350 kcmil(3) #2–500 kcmil(2) #2–500 kcmil(3) #2 – 500 kcmil-
Pow-R-Line 4--#2 – 500 kcmil(2) #2–500 kcmil(2) #2–500 kcmil(3) #2 – 500 kcmil(4) #2 – 500 kcmil
n  n n n n n n n
n n n n n n n
n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n
Breaker TypeAmpere RatingWire Size Ranges
BAB, HQP15 – 70 n n90 – 100#14 - #4 n n#8 - #1/0
QBHW, QPHW15 – 70 n n90 - 100#14 - #4 n n#8 - #1/0
ED, EDH, EDC100 – 225#4 - #1/0 or #6 - 300 kcmil
EHD, FDB, FD, HFD, FDC15 – 100 n n125 – 225 n n175 - 225#14 - #1/0 n n#4 - #4/0 n n#6 - #350
FCL GHB15 – 100 n n15 – 100#14 - #1/0 n n#14 - #1/0
GHQ HGHB n nGHBS15 – 20 n n15 – 30 n n15 – 30#14 - #1/0 n n#14 - #1/0 n n#14 - #1/0
JD, JDB, HJD, JDC70 – 250#4 – 350 kcmil
DK25 – 350 n n400250–500 kcmil n n(2) 3/0 – 250 kcmil Or n n(1) 3/0 – 500 kcmil
KD, KDB, HKD, KDC, CKD©, n nCHKD©100 – 225 n n250 – 350 n n400(1) #3 – 350 kcmil (1) 250 – 350 kcmil (1) 3/0 – 350 kcmil n n(1) 3/0 – 350 kcmil
n
n

Table 3: Standard Main Breaker, Branch Breaker, Main Switch or Branch Switch Terminals.

n  n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n
Breaker TypeAmpere RatingWire Size Ranges
LD, HLD, LDC,300 – 500(2) 250 – 350 kcmil
CLD®,600(2) 400 – 500 kcmil
CHLD®,  
CLDC®  
MDL, HMDL,400 – 600(2) #1 – 500 kcmil
CMDL®,700 – 800(3) 3/0 – 400 kcmil
CHMDL® (2) 500 – 750 kcmil
ND, HND,600 – 1000(3) 3/0 – 4000 kcmil
NDC, CND®1200(4) 4/0 – 500 kcmil
CHND®  
CNDC®  
LCL125 – 225(1) #6 – 350 kcmil
 250 – 400(1) #4 – 250 kcmil
  And
  (1) 3/0 – 600 kcmil
FB-P15 –100#14 – 1/0
LA-P70 – 225#6 – 350 kcmil
 250 – 400(1) #4 – 250 kcmil
  And
  (1) 3/0 – 600 kcmil
NB-P350 – 700(2) #1 – 500 kcmil
 800(3) 3/00 – 400 kcmil
n
    n
  • 100% rated
  • n
n
    n
  • 100% rated breaker
  • n
n n n n n n n
n n n n n n n
n n n n n n n n n n n n n n n n n n n n n n n n n n n n
  n nAmpere Rating  n nWire Size Ranges
30, 60, 100 n n200#14 – 1/0 n n#4 – 300 kcmil
400250 – 750 kcmil or n n(2) 3/0 – 250 kcmil
600(2) #4 – 600 kcmil or (4) 3/0 – 250 kcmil
800(3) 250 – 750 kcmil or (6) 3/0 – 250 kcmil
1200(4) 250 – 750 kcmil or (8) 3/0 – 250 kcmil
n
n

Table 4: FDPW Switches

n Note: For other terminals available on some ratings of molded case circuit breakers and FDPW fusible switches refer to MCCB CD-ROM and product guide. n nNote: All terminal sizes are based on wire ampacities corresponding to those shown in NEC Table 310-16 under 750°C insulation columns (75°C) wire), regardless of insulation temperature is not permitted without voiding UL labels on n n